The new safety light curtains correspond to safety Category 4 (EN ISO 13849-1) and Type 4 (EN IEC 61496-1 and -2) and are designed to be used where risks cannot be eliminated through machine design. A person or any part of the body entering a danger zone is detected by the light curtain, resulting in immediate machine stoppage.
Safetinex light curtains consist of a rugged sender and a receiver unit that demarcate the protection zone around the machine; the range comprises models with resolutions of 14mm for finger protection and 30mm for hand protection, with a maximum protective field width of 3.5 and 12m, respectively. The maximum protective height is either 1685mm (14mm resolution) or 1822mm (30mm resolution). The signal processing method used in the system ensures very fast response times.
For more information, visit www.contrinex.c