Adopting a holistic approach to safety
Didier Turcinovic, founder and President of the Safety Users Group, explains the importance of a holistic approach to safety management
A lifecycle approach to security management
Karl Williams outlines how a novel lifecycle approach to security management is setting a new process industry standard
Wireless plant and the process environment
Hartmut Wallraf, Chief Technology Officer with Invensys Process Systems Europe, Middle East and Africa, outlines where the technology is now and what the future holds for it
Vacuum component market ‘healthy’
Market is worth US$4.2bn, almost half of which is in Asia, has grown by 8 per cent
Pneumatics: reviewing the past
Can we learn about the future by reviewing the past? Ray Barnes applies the theory to 10 year increments in the pneumatics industry
Process intensification
Andrzej Stankiewicz looks at developing sustainable technologies for non-sustainable mankind

Improved accuracy temperature calibrators

Ametek Calibration Instruments has announced that its range of JOFRA ITC dry block temperature calibrators now offers improved accuracy, stability and radial homogeneity (temperature variation between holes on the multi-hole inserts).

The JOFRA ITC range features three models covering temperature ranges -23 to 155˚C (ITC-155), 33 to 320˚C (ITC-320) and 33 to 650˚C (ITC-650).

The JOFRA ITC Series offers exceptional price/performance. It features dual-zone heating block and MVI circuitry adapted from Ametek’s premium ATC range of temperature calibrators.

The dual-zone heating block increases the temperature homogeneity in the critical calibration zone. This minimises the need to insulate sensors-under-test and makes it possible to calibrate liquid-filled and other mechanical sensors. MVI circuitry ensures stable temperatures even when the mains voltage is unstable.

The temperature stability has improved from +0.03˚C to +0.01˚C, for the ITC-155 and from +0.03˚C to +0.02˚C for the ITC-320. Measurements are made over a 30 minute period, after the instrument’s stability indicator has been on for 10 minutes.

Accuracy has improved by at least +0.05˚C across the instrument range as measured over a 12 month period using the built-in internal reference sensor. Radial homogeneity is now 0.02˚C for the ITC-155 compared to the previous value of 0.03˚C while the specification for the ITC-320 has improved from 0.07˚C to 0.04˚C.

The ITC series of dry block calibrators is slim and rugged and is suited to critical process control application. The calibrators are designed for both on-site and maintenance shop use.

JOFRA ITC